Iatrogenic Intraprosthetic Dislocation of Dual Mobility Cup. Case Study

Kamil Kurczyński1, Artur Pepłoński1, Piotr Cieślik1

  • 1Klinka Traumatologii i Ortopedii, Wojskowy Instytut Medyczny, Warszawa / Department of Musculoskeletal Traumatology and Orthopaedics, Military Medical Institute, Warsaw, Poland.

Summary

Intra-prosthetic dislocation of dual-mobile acetabular cups is a rare complication, often due to polyethylene liner wear or during reduction. Immediate recognition is crucial to prevent adverse outcomes.