Frequency of ventilator circuit changes to prevent ventilator-associated pneumonia in neonates and children-A
Thangaraj Abiramalatha1, Viraraghavan Vadakkencherry Ramaswamy2, Sivam Thanigainathan3
1Department of Neonatology, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
Objective:
To assess the effect of different frequencies of ventilator circuit changes in neonates and children through a systematic review and meta-analysis.
Interventions:
(1) "No routine change of ventilator circuit (unless visibly soiled)" versus "routine change at any fixed interval"; (2) routine change of circuit at "less frequent" versus "more frequent" intervals.
Outcomes:
Primary outcomes were VAP rate (number of VAP episodes per 1000 ventilator-days) and all-cause mortality before discharge.
Methods:
MEDLINE, CENTRAL, EMBASE, and CINAHL were systematically searched from inception till November 3, 2020. Two authors assessed trial eligibility and risk of bias, and independently extracted data. Data were synthesized using fixed effects model. GRADE was used to assess certainty of evidence (CoE).
Results:
We identified six studies enrolling 768 participants evaluating circuit changes at two fixed intervals. Meta-analysis of studies on circuit changes "once in less than 7 days" versus "once weekly" showed no difference in VAP rate (risk ratio: 0.83 [0.38-1.81]; one randomized controlled trial (RCT) and 0.94 [0.49-1.81]; two before-after studies) or mortality before discharge (0.67 [0.34-1.3]; one RCT and 1.01 [0.63-1.64]; two before-after studies). CoE was very low. Less frequent circuit changes reduced health-care costs. No study evaluating "circuit changes only when visibly soiled" versus "circuit changes at a fixed interval" was identified.
Conclusion:
There is no evidence to suggest that ventilator circuits can be safely left unchanged until visibly soiled in neonates and children. Extending circuit changes interval to "once weekly" may not increase VAP rate (CoE-very low) and reduces healthcare costs.
More Related Videos
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pneumonia III: Complications and Assessment
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: