Accuracy of abbreviated protocols for unattended automated office blood pressure measurements, a retrospective study
Annina S Vischer1, Rebecca Hug1, Thenral Socrates1
1Medical Outpatient Department and Hypertension Clinic, ESH Hypertension Centre of Excellence, University Hospital Basel, Basel, Switzerland.
Background:
Blood pressure measurement (BPM) is one of the most often performed procedures in clinical practice, but especially office BPM is prone to errors. Unattended automated office BPM (AOBPM) is somewhat standardised and observer-independent, but time and space consuming. We aimed to assess whether an AOBPM protocol can be abbreviated without losing accuracy.
Design:
In our retrospective single centre study, we used all AOBPM (AOBPM protocol of the SPRINT study), collected over 14 months. Three sequential BPM (after 5 minutes of rest, spaced 2 minutes) were automatically recorded with the patient alone in a quiet room resulting in three systolic and diastolic values. We compared the mean of all three (RefProt) with the mean of the first two (ShortProtA) and the single first BPM (ShortProtB).
Results:
We analysed 413 AOBPM sets from 210 patients. Mean age was 52±16 years. Mean values for RefProt were 128.3/81.3 mmHg, for ShortProtA 128.4/81.4 mmHg, for ShortProtB 128.8/81.4 mmHg. Mean difference and limits of agreement for RefProt vs. ShortProtA and ShortProtB were -0.1±4.2/-0.1±2.8 mmHg and -0.5±8.1/-0.1±5.3 mmHg, respectively. With ShortProtA, 83% of systolic and 92% of diastolic measurements were within 2 mmHg from RefProt (67/82% for ShortProtB). ShortProtA or ShortProtB led to no significant hypertensive reclassifications in comparison to RefProt (p-values 0.774/1.000/1.000/0.556).
Conclusion:
Based on our results differences between the RefProt and ShortProtA are minimal and within acceptable limits of agreement. Therefore, the automated procedure may be shorted from 3 to 2 measurements, but a single measurement is insufficient.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...