Purpose:
Phantom studies in CT emphysema quantification show that iterative reconstruction and deep learning-based noise reduction (DLNR) allow lower radiation dose. We compared emphysema quantification on ultra-low-dose CT (ULDCT) with and without noise reduction, to standard-dose CT (SDCT) in chronic obstructive pulmonary disease (COPD).
Method:
Forty-nine COPD patients underwent ULDCT (third generation dual-source CT; 70ref-mAs, Sn-filter 100kVp; median CTDIvol 0.38 mGy) and SDCT (64-multidetector CT; 40mAs, 120kVp; CTDIvol 3.04 mGy). Scans were reconstructed with filtered backprojection (FBP) and soft kernel. For ULDCT, we also applied advanced modelled iterative reconstruction (ADMIRE), levels 1/3/5, and DLNR, levels 1/3/5/9. Emphysema was quantified as Low Attenuation Value percentage (LAV%, ≤-950HU). ULDCT measures were compared to SDCT as reference standard.
Results:
For ULDCT, the median radiation dose was 84 % lower than for SDCT. Median extent of emphysema was 18.6 % for ULD-FBP and 15.4 % for SDCT (inter-quartile range: 11.8-28.4 % and 9.2 %-28.7 %, p = 0.002). Compared to SDCT, the range in limits of agreement of emphysema quantification as measure of variability was 14.4 for ULD-FBP, 11.0-13.1 for ULD-ADMIRE levels and 10.1-13.9 for ULD-DLNR levels. Optimal settings were ADMIRE 3 and DLNR 3, reducing variability of emphysema quantification by 24 % and 27 %, at slight underestimation of emphysema extent (-1.5 % and -2.9 %, respectively).
Conclusions:
Ultra-low-dose CT in COPD patients allows dose reduction by 84 %. State-of-the-art noise reduction methods in ULDCT resulted in slight underestimation of emphysema compared to SDCT. Noise reduction methods (especially ADMIRE 3 and DLNR 3) reduced variability of emphysema quantification in ULDCT by up to 27 % compared to FBP.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
10:37Automated Measurement of Pulmonary Emphysema and Small Airway Remodeling in Cigarette Smoke-exposed Mice
Published on: January 16, 2015
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Imaging Studies for Cardiovascular System V: CT
Chronic Obstructive Pulmonary Disease-I: Introduction