Prospective evaluation of third-generation small bowel capsule endoscopy videos by independent readers demonstrates poor reproducibility of cleanliness classifications
Related Experiment Video
Updated: Nov 12, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Xavier Dray1, Guy Houist2, Jean-Philippe Le Mouel3
1Sorbonne University, Center for Digestive Endoscopy, Hôpital Saint-Antoine, APHP, 184 rue du Faubourg Saint-Antoine, 75012 Paris, France.
Objective:
The detection of lesions during small bowel (SB) capsule endoscopy (CE) depends on the cleanliness of the intestine. Quality reporting and comparison of different preparation methods require reliable scores. Three scores known as quantitative index (QI), qualitative evaluation (QE), and overall adequacy assessment (OAA), have been proposed to assess SB cleanliness, and are sometimes used in clinical practice and in clinical trials. However, none of these scores has received any external validation. The aim of our study was to re-assess the reproducibility of these three specific scores.
Methods:
One-hundred-and-fifty-five complete third-generation SB-CE video recordings were extracted from a multicenter randomized controlled trial (PREPINTEST) which evaluated three modalities of SB preparation for CE. Three experts independently read the 155 SB-CE video recordings twice, in a random order, over 48 -h periods at 6-week intervals, using the QI, QE and OAA scores. Cohen's linearly weighted kappa coefficients were calculated to assess intra-observer and inter-observer agreements.
Results:
Intra-observer reproducibility was fair to moderate, with kappa coefficients between 0.37 and 0.46 for QI, 0.41 and 0.51 for QE, 0.41 and 0.50 for OAA. Inter-observer reproducibility was fair to substantial according to kappa coefficients between experts varying from 0.40 to 0.64, 0.29 to 0.65, and 0.52 to 0.71, for QI, QE and OAA, respectively.
Conclusions:
QI, QE and OAA scores, currently used for evaluation of the quality of the preparation of SB-CE, are not sufficiently reproducible. Other scores or methods are therefore needed for SB-CE cleanliness assessment.
More Related Videos
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
09:01Non-invasive Assessment of the Efficacy of New Therapeutics for Intestinal Pathologies Using Serial Endoscopic Imaging of Live Mice
Published on: March 10, 2015
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Urologic Endoscopic Procedure: Cystoscopic Examination