Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of

Friso M Rijnberg1, Hans C van Assen2, Joe F Juffermans2

  • 1Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333ZA, Leiden, The Netherlands. f.m.rijnberg@lumc.nl.

Scientific Reports
|March 23, 2021
PubMed

Insights

Non-ECG gated 3D flow MRI significantly reduces scan times for Fontan patients. This method accurately assesses Fontan pathway hemodynamics, offering improved image quality compared to 4D flow MRI.

Area of Science:

  • Cardiovascular Imaging
  • Medical Physics

Background:

  • 4D flow MRI in Fontan patients is limited by long scan times.
  • Pulsatility in the Fontan pathway is minimal, suggesting potential for non-ECG gated techniques.

Purpose of the Study:

  • To evaluate the feasibility of non-gated 3D flow MRI for assessing Fontan pathway hemodynamics.
  • To compare scan time, image quality, and clinical parameter accuracy of 3D flow MRI against 2D and 4D flow MRI.

Main Methods:

  • Prospective study of 32 Fontan patients undergoing 2D, 3D, and 4D flow MRI.
  • Assessment of time-averaged flow rates, including right-to-left pulmonary flow distribution and systemic-to-pulmonary collateral flow (SPCF).

Main Results:

  • 3D flow MRI achieved a tenfold reduction in scan time compared to 4D flow MRI (1.6 min vs. 15.9 min).
  • Superior signal-to-noise ratio and vessel sharpness were observed with 3D flow MRI.
  • Good-excellent agreement was found between 3D flow MRI and reference methods (2D/4D flow) for key hemodynamic parameters.

Conclusions:

  • Non-gated 3D flow MRI is a viable alternative for Fontan pathway assessment.
  • This technique offers significant reductions in scan time and improved image quality without compromising diagnostic accuracy.