Intravenous Smart Pumps During Actual Clinical Use: A Descriptive Comparison of Primary and Secondary Infusion
Karen K Giuliano1,2,3,4,5, Daleen Penoyer1,2,3,4,5, Rebecca S Mahuren1,2,3,4,5
1University of Massachusetts Amherst, Institute for Applied Life Sciences and College of Nursing, Amherst, Massachusetts (Dr Giuliano); Center for Nursing Research and Advanced Nursing Practice, Orlando Health, Orlando, Florida (Dr Penoyer and, formerly, Ms Bennett); Parkview Regional Medical Center, Fort Wayne, Indiana (Ms Mahuren).
Abstract:
This descriptive observational study was conducted to increase understanding of medication administration practices during actual clinical use between 2 commonly used, different types of intravenous (IV) smart pumps. Compliance with manufacturer-recommended setup requirements for both primary and secondary infusions and secondary medication administration delay was compared between a head-height differential system and a cassette system. A total of 301 medication administration observations were included in this study: 102 (34%) for the linear peristaltic IV smart pump (medical-surgical: N = 51; critical care: N = 51) and 199 (66%) for the cassette pump (medical-surgical: N = 88; critical care: N = 111). Results found a 0% compliance for primary line setup and 84% compliance for secondary line setup and 1 omitted medication due to a closed clamp with the linear peristaltic system. For the cassette system, there are no head-height requirements. Two roller clamps were found to be in the closed position on initiation of the secondary infusion, but the clinician was alerted by an alarm, so no medication delays occurred. These findings support that the current system requirements for flow rate accuracy using head-height differential systems are difficult to achieve consistently at the point of care. There is a need for additional human factor designed technology to replace manual actions to improve the process of care for nurses and the safety of care for patients.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...