MRI Visualization of Polyethylene Post Fractures in Posterior Stabilized Total Knee Arthroplasty
Meghan E Sahr1, Hollis G Potter1, Yoshimi Endo1
1Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021.
Abstract:
Polyethylene post fracture is a recognized complication of posterior stabilized total knee arthroplasty. Two radiologists retrospectively reviewed MRI examinations of 19 reported post fractures in 18 patients; all fractures were subsequently confirmed surgically with no false-positive cases. All post fractures were visualized as a combination of post deformity and signal-void fragment in a joint recess. A metal artifact reduction 3D multispectral imaging sequence improved fracture visualization versus conventional sequences in 47% of cases.