Plasma or serum, which is the better choice for the measurement of metanephrines?
Songlin Yu1, Danchen Wang1, Jialei Yu1
1Department of Clinical Laboratory, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
Abstract:
Measurement of metanephrines (MNs: metanephrine [MN] and normetanephrine [NMN]) is recommended for the initial biochemical diagnosis of pheochromocytoma and paraganglioma. Despite some drawbacks, plasma is commonly used for sampling. Here, we determined the feasibility of using serum, as an alternative to plasma, by comparing MNs in plasma and serum and evaluating the stability of MNs in serum. MNs obtained from serum, EDTA plasma, and heparin plasma were measured using LC-MS/MS immediately or after storage at 4 °C for 24 h, 72 h, and 7 days, and at -80 °C for 7 days, after sample collection. The differences between sample stability at given time points were compared using one-way ANOVA and Students' paired t-test, and the mean percent deviation was compared with total change limit (TCL). No significant difference was observed in MN and NMN between serum and EDTA plasma, and the mean percent deviation of the results obtained from serum compared to that from EDTA plasma was within the TCL. However, the difference of MN between EDTA plasma and heparin plasma exceeded the TCL. Both MNs in EDTA plasma and heparin plasma showed a significant decreasing trend at 4 °C with time (p < .01), while those in serum were relatively stable, with the mean percent deviation not exceeding the TCL at any time point or temperature. In conclusion, MNs measurement did not significantly differ between EDTA plasma and serum when measured immediately after collection, and MNs in serum were more stable than that in plasma.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
07:14Detection and Quantification of Calcitonin Gene-Related Peptide CGRP in Human Plasma Using a Modified Enzyme-Linked Immunosorbent Assay
Published on: June 16, 2023
Related Concept Videos
Serum Studies: Renal Function Tests
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Concentrations: Measurements
Plasma...
