Related Experiment Video
Updated: Nov 10, 2025

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Perforation of an Aortopulmonary Collateral: A Scary Sight in the Lab!
Dinkar Bhasin, Gaurav Kumar Arora, Anunay Gupta
1Department of Cardiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi-110029, India. drhsisser@gmail.com.
Abstract:
A 12-year-old boy with complex cyanotic congenital heart disease with single-ventricle physiology was planned for univentricular repair. Aortopulmonary collateral occlusion using thrombotic embolization coils was planned, but during the procedure, there was perforation of an aortopulmonary collateral arising from the descending thoracic aorta. The teaching point from this case is that all aortopulmonary collaterals do not necessarily need to be occluded; when occlusion is performed, coils must be appropriately sized.