Related Experiment Video
Updated: Nov 10, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Development of a computed tomography perfusion protocol to support large animal resuscitation research
Hossam Abdou1, Noha Elansary, David Poliner
1From the R Adams Cowley Shock Trauma Center (H.A., N.E., D.P., N.P., J.E., M.R., T.P., T.M.S., J.J.M.), University of Maryland Medical System, Baltimore; and Uniformed Services University of the Health Sciences (T.R.), Bethesda, Maryland.
Background:
Adequate cerebral perfusion is crucial for a positive neurological outcome in trauma; however, it is difficult to characterize in the acute setting with noninvasive methods. Intra-arterial computed tomography perfusion may offer a solution. The aim of this study was to develop an intra-arterial computed tomography perfusion protocol for resuscitation research.
Methods:
The study examined intra-arterial contrast administration for computed tomography perfusion (CTP) acquisition. It consisted of three phases: intra-arterial contrast dose finding, evaluation of reproducibility, and evaluation during hypotension. Blood pressure and laser Doppler flow data were collected. In phase 1, animals underwent CTPs using several intra-arterial contrast injection protocols. In phase 2, animals underwent two CTPs 7 hours apart using the 2.5 mL/s for 3-second protocol. In phase 3, animals underwent CTPs at several pressures following a computer-controlled bleed including euvolemia and at systolic pressures of 60, 40, and 20 mm Hg. Phase 1 CTPs were evaluated for contrast-to-noise ratio. In phase 2, CTPs were compared within each animal and with laser Doppler flow using linear regression. Phase 3 CTPs were graphed against systolic pressure and fitted with a nonlinear fit.
Results:
The protocol using 2.5mL/s for 3 seconds was optimal, demonstrating a contrast-to-noise ratio of 40.1 and a superior arterial input function curve compared with the 1 mL/s bolus. Cerebral blood flow demonstrated high concordance between baseline and end of study CTPs (R2 = 0.82, p < 0.001). Cerebral blood flow also compared moderately well against laser Doppler flow during 8 (R2 = 0.53, p = 0.03); however, laser Doppler flow did not perform well during hypovolemia, and the favorable concordance was not maintained (R2 = 0.45, p = 0.06). Cerebral blood flow was graphed against systolic blood pressure and fitted with a nonlinear fit (R2 = 0.95, p = 0.003).
Conclusion:
Computed tomography perfusion using intra-arterial contrast injection may offer a novel alternative to traditional CTP protocols that could prove a useful additional tool in the setting of resuscitation research.
More Related Videos
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
07:49Large-Animal Model of Donation after Circulatory Death and Normothermic Regional Perfusion for Cardiac Assessment
Published on: May 10, 2022