Related Experiment Video
Updated: Nov 10, 2025

Animal Model of Implant-Associated Infections in Mice
Published on: June 27, 2025
Clindamycin-Based 3D-Printed and Electrospun Coatings for Treatment of Implant-Related Infections
Tina Maver1,2, Tinkara Mastnak3, Mihela Mihelič3
1Institute of Biomedical Sciences, Faculty of Medicine, University of Maribor, Taborska ulica 8, SI 2000 Maribor, Slovenia.
Abstract:
This study presents the development and characterisation of two novel bioactive coatings deposited on TiAlV and AISI 316LVM substrates. The coatings were prepared using 3D printing and electrospinning. The 3D-printed coating consisted of the cellulose nanofibril suspension, alginate, and carboxymethylcellulose (CMC), while CMC and polyethylene oxide were used to prepare the electrospun coating. Both coatings were loaded with the antibiotic clindamycin (CLIN), which is a bacteriostatic lincosamide known for its activity against streptococci, staphylococci, pneumococci, Bacteroides species, and other anaerobes. Initial characterisation of the coatings was performed by attenuated total reflectance Fourier transform infrared spectroscopy, field emission scanning electron microscopy, and atomic force microscopy. Furthermore, the contact angle measurements, swelling rate, and biodegradability of the coatings were investigated. The released concentration of CLIN in PBS (pH = 7.4 at 25 °C) was determined by UV-VIS spectrophotometry. The coatings' biocompatibility was determined using an MTT (3(4,5 dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide) assay using an osteoblast cell culture (hFOB 1.19, ATCC CRL 11372).