Characterization of Methacrylate-Based Resins Containing Methacryl-Polyhedral Oligomeric Silsesquioxanes (MA-POSS-8)
Marietta Kreutz1, Annette Wiegand1, Bogna Stawarczyk2
1Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, 37075 Göttingen, Germany.
Abstract:
The use of functionalized dental adhesives that might prevent degradation of the dentin hybrid layer has been proposed. The aim of the study was to characterize the physicochemical properties and the potential to induce mineral precipitation of methacrylate-based resins containing methacryl-functionalized polyhedral oligomeric silsesquioxane (MA-POSS-8). In total, six different compositions of resins based on bisphenol A glycerolate dimethacrylate (BisGMA, 40 to 60 wt.%), triethylene glycol dimethacrylate (TEGDMA, 5 to 35 wt.%) and 2-hydroxyethyl methacrylate (HEMA, 25 or 35 wt.%) were prepared and infiltrated with 5 wt.% MA-POSS-8. Unfilled resins served as control. Degree of conversion, viscosity, Martens hardness, indentation modulus, water sorption, and sol fraction were investigated. Polymerized specimens were examined by SEM/EDX for the presence of Ca/P precipitates after immersion in artificial saliva for 28 days at 37 °C. Statistical analysis was performed with two-way ANOVA and Tukey's post-hoc test (p < 0.05). The degree of conversion ranged from 55.0 to 59.8% and was not affected by the addition of MA-POSS-8. Viscosity ranged from 60.0 to 422.3 mPa*s and was not affected by MA-POSS-8 except for one methacrylate-based resin with 60 wt.% BisGMA. Martens hardness and indentation modulus ranged from 161.3 to 138.1 N/mm2 and 4.2 to 3.9 kN/mm2 and were affected by MA-POSS-8 in only one resin (50 wt.% BisGMA, 25 wt.% TEGDMA, 25 wt.% HEMA). Water sorption was not affected by MA-POSS-8; sol fraction was below the detection limit. Formation of Ca/P precipitates was observed on all specimens of test and control groups. Material properties were not affected adversely by MA-POSS-8 except for slight differences in Martens hardness, indention modulus, viscosity in some groups. However, bioactive properties could not be improved by MA-POSS-8.
Related Concept Videos
Polymer Classification: Stereospecificity
Olefin Metathesis Polymerization: Overview
Ruthenium-based Grubbs catalyst is the most commonly used catalyst for olefin metathesis polymerization. Grubbs catalyst consists of a...
Carboxylic Acids to Methylesters: Alkylation using Diazomethane
Olefin Metathesis Polymerization: Acyclic Diene Metathesis (ADMET)
Similar to cross-metathesis, ADMET also involves the formation of metallacyclobutane intermediate by [2+2] cycloaddition of one of the double bonds of a terminal diene with...