One-hundred consecutive patients undergoing aesthetic surgical procedures with adjunctive intravenous sedation in an office-based ambulatory surgical facility were monitored by an anesthesiologist with an ECG, stethoscope, automatic sphygmomanometer, and pulse oximeter. The pulse oximeter detected hypoxemia occurring intraoperatively and in the recovery room earlier than the traditional methods of monitoring. By detecting early drops in the SAO2 with the pulse oximeter, appropriate corrective measures could be instituted and titration of intravenous anesthetics adjusted, avoiding progression to more profound hypoxemia and thus resulting in the safer delivery of anesthesia. The pulse oximeter is a useful and recommended adjunct to the traditional methods of monitoring in an office-based ambulatory surgical facility.
More Related Videos
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...