Related Experiment Video
Updated: Nov 9, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Cerebral oxygen saturation (rSO2) during cardiopulmonary bypass (CPB) measured using the INVOS oximeter closely
Yumiko Kadokura1, Masakazu Hayashida2, Maho Kakemizu-Watanabe1
1Department of Anesthesiology and Pain Medicine, Graduate School of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan.
Abstract:
Baseline cerebral regional saturation (rSO2) measured using the INVOS 5100C (Medtronic, MN, USA) varies widely among patients with cardiac and/or renal diseases. To identify significant correlates of baseline rSO2 and to investigate intraoperative rSO2 changes, we conducted a retrospective study in 494 patients undergoing on-pump cardiovascular surgery. Correlations between preoperative blood laboratory test variables and baseline rSO2 before anesthesia were examined. Intraoperative rSO2 changes were analyzed. Of all the variables examined, log-transformed B-type natriuretic peptide (BNP) most significantly and negatively correlated with baseline rSO2 (r = - 0.652, p < 0.0001). Intraoperatively, rSO2 showed the lowest value during cardiopulmonary bypass (CPB) (median rSO2: 56.2% during CPB vs. 63.9% at baseline, p < 0.0001). Although rSO2 during CPB correlated positively with hemoglobin concentration and oxygen delivery during CPB (r = 0.192, p < 0.0001; and r = 0.172, p = 0.0001, respectively), it correlated much more closely with baseline rSO2 (r = - 0.589, p < 0.0001). Thus, patients showing low baseline rSO2 primarily associated with preoperatively high BNP continued to show low rSO2 even during CPB independent of hemodynamics artificially controlled by CPB. Our findings suggest that low baseline rSO2 in patients with high BNP due to cardiac and/or renal diseases is more likely to result from tissue edema causing alterations in optical pathlength and thus in calculated rSO2 values, not readily modifiable with CPB, rather than actual cerebral hemodynamic alterations readily modifiable with CPB. These may partly explain why the INVOS oximeter is a trend monitor requiring baseline measures.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Measurement of Blood Pressure