A clinical set-up for noninvasive blood pressure monitoring using two photoplethysmograms and based on convolutional
Jamal Esmaelpoor1, Zahra Momayez Sanat2, Mohammad Hassan Moradi3
1Department of Electrical Engineering, Islamic Azad University, Boukan Branch, Boukan, Iran.
Abstract:
Blood pressure is a reliable indicator of many cardiac arrhythmias and rheological problems. This study proposes a clinical set-up using conventional monitoring systems to estimate systolic and diastolic blood pressures continuously based on two photoplethysmogram signals (PPG) taken from the earlobe and toe. Several amendments were applied to conventional clinical monitoring devices to construct our project plan. We used two monitors to acquire two PPGs, one ECG, and invasive blood pressure as the reference to evaluate the estimation accuracy. One of the most critical requirements was the synchronization of the acquired signals that was accomplished by using ECG as the time reference. Following data acquisition and preparation procedures, the performance of each PPG signal alone and together was investigated using deep convolutional neural networks. The proposed architecture was evaluated on 32 records acquired from 14 patients after cardiovascular surgery. The results showed a better performance for toe PPG in comparison with earlobe PPG. Moreover, they indicated the algorithm accuracy improves if both signals are applied together to the network. According to the British Hypertension Society standards, the results achieved grade A for both blood pressure measurements. The mean and standard deviation of estimation errors were +0.3 ± 4.9 and +0.1 ± 3.2 mmHg for systolic and diastolic BPs, respectively. Since the method is based on conventional monitoring equipment and provides a high estimation consistency, it can be considered as a possible alternative for inconvenient invasive BP monitoring in clinical environments.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...