Related Experiment Video
Updated: Nov 9, 2025

Simple and Fast Rolling Circle Amplification-Based Detection of Topoisomerase 1 Activity in Crude Biological Samples
Published on: December 2, 2022
Rolling circle amplification with fluorescently labeled dUTP-balancing the yield and degree of labeling
M S Goryunova1, V K Arzhanik2, S K Zavriev1
1Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry, Laboratory of Molecular Diagnostics, Russian Academy of Science, Miklukho-Maklaya Street, 16/10, 117997, Moscow, Russia.
Abstract:
Detection methods based on rolling circle amplification (RCA) have been applied to a large number of targets in molecular biology. The key feature of RCA-based methods as well as other nucleic acid amplification methods is their exceptional sensitivity, which allows the detection of molecules at low concentrations, achieved by signal amplification due to nucleic acid magnification and subsequent detection. Variations on the method, such as immuno-RCA, extend the range of potential targets that can be detected. Employing fluorescently labeled nucleotides for direct incorporation into an amplification product is an attractive method for RCA product detection. However, the effectiveness of this approach remains doubtful. In our study, we utilized different modified dUTPs, including sulfo-cyanine3-dUTP, sulfo-cyanine5-dUTP, sulfo-cyanine5.5-dUTP, BDP-FL-dUTP, and amino-11-dUTP, to investigate whether the properties of the fluorophore used for modification affected the reaction yield and effectiveness of incorporation of nucleotide analogs by phi29 DNA polymerase. Among the modified dUTPs, sulfo-cyanine3-dUTP demonstrated the highest incorporation effectiveness, equal to 4-9 labels per 1000 nucleotides. The mean length of the RCA product was estimated to be approximately 175,000 nucleotides. The total increase in fluorescence from a single target/product complex was 850 times. The results obtained in the study illustrate the possibility of successful application of nucleotide analogs for RCA detection and present quantitative characteristics of fluorescently labeled dUTPs to be incorporated into RCA products.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...

