Purpose:
One of the key factors to the successful revision of total knee arthroplasty (rTKA) is the reconstruction of the joint line, which can be determined using the epicondylar ratio (ER). The measurement is established in X-ray and MRI. However, it is not known whether computed tomography (CT) allows a more reliable determination. The objective was to assess the reliability of the ER in CT and to determine the correlation between the ER in CT and a.p. X-ray of the knee.
Methods:
The ER was determined on X-ray and CT images of a consecutive series of 107 patients, who underwent rTKA. Measurements were made by two blinded observes, one measured twice. The inter- and intraobserver agreement, as well as the correlation between the two methods, were quantified with the Intraclass Correlation Coefficient.
Results:
The average lateral ER was 0.32 (± 0.04) in X-ray and 0.32 (± 0.04) in CT. On the medial side, the average ER was 0.34 (± 0.04) in X-ray and 0.35 (± 0.04) in CT. The interobserver agreement for the same imaging modality was lateral 0.81 and medial 0.81 in X-ray as well as lateral 0.74 and medial 0.85 in CT. The correlation between the two methods was lateral 0.81 and medial 0.79.
Conclusions:
The ER can be reliably determined in X-ray and CT. Measurements of the two image modalities correlate. Prior to rTKA, the sole use of the X-ray is possible.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...