[Equations to estimate body composition using bioelectrical impedance in Chilean adults]
Ingrid Schifferli1, Juan José Orellana-Cáceres1, Gladys Morales1
1Departamento de Salud Pública, Facultad de Medicina, Universidad de La Frontera, Temuco, Chile.
Background:
Equations for the evaluation of fat-free mass (FFM) and fat mass (FM) with Bioelectrical impedance analysis (BIA) were formulated in Caucasian populations. International recommendations suggest that population-specific equations should be formulated.
Aim:
To validate an equation previously formulated in Chileans adults and compare it to a new equation generated on an independent sample.
Material And Methods:
In 108 adult volunteers aged 38.1±14.1 years (44% males), with a body mass index (BMI) of 25.1± 4.1 kg/m2, body composition was measured by BIA (Bodystat) and dual X-ray absorptiometry (DXA: Lunar Prodigy). Body composition estimated using Schifferli equation and BIA were compared with DEXA, by the Bland-Altman method and simple linear regression.
Results:
FFM and FM measured by DXA were 45.2 ± 9.8 kg and 29.6 ± 11.7 % respectively. Resistance was 467.7 ± 76.3 ohm. Schifferli equation and BIA significantly overestimated FFM by 7.3 and 7.4 kg, respectively. The error was higher for high levels of FFM (slope β < 1, p < 0.01). Both equations underestimated FM measured by DXA (averages of 7.5 and 7.8%, respectively, p < 0.01), without a differential bias for Schifferli equation, but with a bias in low levels of FM measured with BIA (slope β < 1, p < 0.01). Estimation biases could be eliminated using the regression coefficients.
Conclusions:
Both equations behave similarly and have biases, although less with Schifferli. Statistically correcting for biases, the new adjusted equations provide clinically valid estimates of FFM and FM. Equations should not only be population-specific, but also device-specific.
More Related Videos
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Bode Plots Construction
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration