e-ASPECTS software improves interobserver agreement and accuracy of interpretation of aspects score

Waleed Brinjikji1,2, Mehdi Abbasi1, Catherine Arnold3

  • 1Department of Radiology, Mayo Clinic, Rochester, MN, USA.

Summary

Artificial intelligence (AI) software, Brainomix e-ASPECTS, significantly improved accuracy and agreement in evaluating neuroimaging for acute ischemic stroke. This AI tool enhances ASPECTS score interpretation by neuroradiologists and neurologists.

Related Concept Videos

Econometric Views (EViews)01:29

Econometric Views (EViews)

Econometric Views, often stylized as EViews, is a package that merges statistical analysis with econometric studies. It is designed to provide tools for time series analysis, forecasting, and econometric model simulation. The software originated from MicroTSP software and has evolved significantly since its inception in 1981. The history of EViews is marked by a continuous effort to enhance its computational speed and user interface. It was initially developed for large computing systems but...
343
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
439
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
427
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
436
Reliability and Validity01:29

Reliability and Validity

Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.4K