Are Cramér-Rao lower bounds an accurate estimate for standard deviations in in vivo magnetic resonance spectroscopy?
Karl Landheer1, Christoph Juchem1,2
1Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, New York, New York, USA.
Abstract:
Due to inherent time constraints for in vivo experiments, it is infeasible to repeat multiple MRS scans to estimate standard deviations on the desired measured parameters. As such, the Cramér-Rao lower bounds (CRLBs) have become the routine method to approximate standard deviations for in vivo experiments. Cramér-Rao lower bounds, however, as the name suggests, are theoretically a lower bound on the standard deviation and it is not clear if and under what circumstances this approximation is valid. Realistic synthetic 3 T spectra were used to investigate the relationship between estimated CRLBs, true CRLBs and standard deviations. Here we demonstrate that, although the CRLBs are theoretically truly a lower bound on the standard deviation (not an equality) for the problem typically encountered in quantification, they are still an adequate approximation to standard deviation as long as the model perfectly characterizes the data. In the case when the macromolecule basis deviates from the measured macromolecules it was shown that the CRLBs can deviate from standard deviations by approximately 50% for N-acetylaspartic acid, creatine and glutamate and of the order of 100% or more for myo-inositol and γ-aminobutyric acid. In the case when the model perfectly reflects the data the CRLBs are within approximately 10% of standard deviations for all metabolites. The result of the CRLB being within 10% of standard deviations means that, for an accurate model, novel quantification methods such as machine learning or deep learning will not be able to obtain substantially more precise estimates for the desired parameters than traditional maximum-likelihood estimation.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Magnetic Resonance Imaging