Related Experiment Video
Updated: Nov 8, 2025

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Patterns of use, effectiveness and safety of gadolinium contrast agents: a European prospective cross-sectional
Jarl Åsbjørn Jakobsen1, Carlo Cosimo Quattrocchi2, Frank H H Müller3
1Oslo University Hospital, Oslo, Norway. j.a.jakobsen@medisin.uio.no.
Background:
The EU gadolinium-based contrast agents (GBCA) market has changed in recent years due to the European Medicines Agency decision to suspend the marketing authorisation of linear GBCA and the marketing authorisation of new generic macrocyclic GBCA. The study aims to understand the patterns of (GBCA) use, and to study the effectiveness and safety of GBCA in routine practice across Europe.
Methods:
Prospective, cross-sectional, multicentre, observational study in patients undergoing contrast-enhanced magnetic resonance. Reported usage patterns included indication, referral and examination details. Assessment of effectiveness included changes in radiological diagnosis, diagnostic confidence and image quality. Safety data were collected by spontaneous patient adverse event (AE) reporting.
Results:
2118 patients were included from 8 centres across 5 European countries between December 2018 and November 2019. Clariscan, Dotarem (gadoteric acid), Gadovist (gadobutrol) and ProHance (gadoteridol) were utilised in 1513 (71.4%), 356 (16.8%), 237 (11.2%) and 12 (0.6%) patients, respectively. Most were performed in CNS-related indications (46.2%). Mean GBCA doses were 0.10 mmol/kg body weight, except for Gadovist (mean 0.12 mmol/kg). GBCA use increased confidence in diagnosis in 96.2% of examinations and resulted in a change in radiological diagnosis in 73.9% of patients. Image quality was considered excellent or good in 96.1% of patients and across all GBCA. Four patients reported AEs (0.19%), with only 1 (0.05%) considered serious.
Conclusions:
This European study confirmed that GBCAs are used appropriately in Europe for a wide range of indications. The study demonstrated a significant increase in diagnostic confidence after GBCA use and confirmed the good safety profile of GBCAs, with comparable results for all agents used.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Magnetic Resonance Imaging