Penumbra quantification from MR SWI-DWI mismatch and its comparison with MR ASL PWI-DWI mismatch in patients with

Rupsa Bhattacharjee1,2, Rakesh Kumar Gupta3, Biplab Das4,5

  • 1Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India.

NMR in Biomedicine
|April 21, 2021
PubMed

Insights

Quantitative assessment of the ischemic penumbra using susceptibility-weighted imaging (SWI) and diffusion-weighted imaging (DWI) offers an accurate alternative to perfusion-weighted imaging (PWI)-DWI. This novel SWI-DWI approach reduces overall scan time for acute ischemic stroke patients.

Area of Science:

  • Neuroimaging
  • Radiology
  • Stroke Medicine

Background:

  • Penumbra assessment is crucial for optimizing acute ischemic stroke treatment outcomes.
  • Current methods like perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) mismatch ratio are established but can be time-consuming.
  • Susceptibility-weighted imaging (SWI) has shown potential for qualitative penumbra assessment.

Purpose of the Study:

  • To develop and validate a quantitative framework for penumbra assessment using SWI-DWI.
  • To evaluate SWI-DWI as a potential time-saving alternative to PWI-DWI.
  • To correlate SWI-DWI penumbra assessment with clinical outcomes and treatment response.

Main Methods:

  • Retrospective analysis of 25 acute ischemic stroke patients within 24 hours of symptom onset.
  • MRI acquisition included DWI, SWI, pseudo-continuous arterial spin labeling (pCASL) for PWI, FLAIR, and non-contrast angiography.
  • Developed a framework for SWI penumbra region of interest (ROI) segmentation and compared it with semiautomatically segmented ASL penumbra and ADC-derived infarct core ROIs.

Main Results:

  • High Dice coefficient (0.96 ± 0.07) between SWI and ASL penumbra ROIs indicates strong agreement.
  • SWI-DWI mismatch ratio strongly correlated with ASL PWI-DWI mismatch ratio (r=0.90, p<0.05), validating the hypothesis.
  • Higher SWI penumbra volume correlated with vessel occlusion, and follow-up data showed tissue salvage predicted by the SWI-DWI framework; 93.3% of patients with a mismatch ratio >1 benefited from revascularization.

Conclusions:

  • Automated quantitative penumbra assessment using SWI-DWI is equivalent to ASL PWI-DWI.
  • This SWI-DWI method offers a viable alternative to perfusion imaging, potentially reducing scan time by 17%.
  • The SWI-DWI approach facilitates accurate penumbra assessment, aiding treatment decisions and predicting therapeutic benefits in acute ischemic stroke.