A dual-channel incoherent broadband cavity-enhanced absorption spectrometer for sensitive atmospheric NO measurements
Anoop Pakkattil1, Aiswarya Saseendran1, Arun P Thomas1
1Department of Physics, National Institute of Technology Calicut, Calicut 673601, Kerala, India. r.varma@nitc.ac.in.
Abstract:
We describe and characterize a dual-channel incoherent broadband cavity-enhanced absorption spectrometer (DC-IBBCEAS) for the sensitive measurements of NOx: the sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2) in the atmosphere. The instrument employs two 1 m long optical cavities, with air being extracted from a common sampling line. The first channel (cavity-1) spans 340-380 nm and the second channel (cavity-2) spans the 405-460 nm spectral range, both measuring NO2 simultaneously. High absorption cross-sections of NO2 in both channels are effectively utilized for its sensitive quantification. NO is quantified by titrating it with ozone to NO2 in channel-2, where the difference of NO2 measured from that in channel-1 corresponds to the NO concentration in the sampled air. The instrument offers 1-ppb detection sensitivity for both NO and NO2 with a maximum possible uncertainty of ∼9%. The use of close yet different spectral regions in the two channels readily extended measurements to a broader range without compromising its sensitivity to NOx quantification. This would extend the DC-IBBCEAS applicability to simultaneously monitor interfering species with significant absorption cross-sections in the region in either channel, such as glyoxal (CHOCHO), methylglyoxal (CH3COCHO), and nitrous acid (HONO).
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
UV–Vis Spectrometers
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation