Related Experiment Video
Updated: Jul 30, 2026

Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
Ultra-sensitive detection of ATP in serum and lysates based on nitrogen-doped carbon dots
Yaning Qin1, Zhaoyue Yan2, Rui Liu1
1College of Chemistry, Zhengzhou University, Zhengzhou, P. R. China.
Abstract:
In this work, novel types of nitrogen-doped carbon dots (N-CDs) were prepared from citric acid and glycine (GLY) as precursors through a simple pyrolysis method. The GLY-CDs showed strong fluorescence with a fluorescence quantum yield as high as 33.34% and good water solubility. The fluorescence of GLY-CDs could be selectively quenched by iron(III) ion (Fe3+ ) resulting in the non-fluorescent complex. Due to the high affinity of Fe3+ to adenosine-5'-triphosphate (ATP), the fluorescence of the GLY-CDs in GLY-CDs-Fe3+ could be recovered by ATP. Thereby, quantitatively fluorescent turn-on detection of ATP could be achieved. The fluorescence recovery ratio was linearly proportional to the concentration of ATP with a detection limit as low as 15.0 nM, indicating the CDs have high sensitivity. The GLY-CDs were successfully employed in the detection of ATP in serum and cell lysates.