Dynamic-Contrast-Enhanced (DCE) Imaging has been widely studied to characterize microcirculatory disorders associated with various diseases. Although numerous studies have demonstrated its diagnostic interest, the physiological interpretation using pharmacokinetic models often remains debatable. Indeed, to be interpretable, a model must provide, at first instance, an accurate description of the DCE data. However, the evaluation and optimization of this accuracy remain rather limited in DCE. Here we established a non-linear Free-Time-Point-Hermite (FTPH) data-description model designed to fit DCE data accurately. Its performance was evaluated on data generated using two contrasting pharmacokinetic microcirculatory hypotheses (MH). The accuracy of data description of the models was evaluated by calculating the mean squared error (QE) from initial and assessed tissue impulse responses. Then, FTPH assessments were provided to blinded observers to evaluate if these assessments allowed observers to identify MH in their data. Regardless of the initial pharmacokinetic model used for data generation, QE was lower than 3% for the noise-free datasets and increased up to 10% for a signal-to-noise-ratio (SNR) of 20. Under SNR = 20, the sensitivity and specificity of the MH identification were over 80%. The performance of the FTPH model was higher than that of the B-Spline model used as a reference. The accuracy of the FTPH model regardless of the initial MH provided an opportunity to have a reference to check the accuracy of other pharmacokinetic models.
More Related Videos
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
08:36Dynamic Inter-subject Functional Connectivity Reveals Moment-to-Moment Brain Network Configurations Driven by Continuous or Communication Paradigms
Published on: March 21, 2019
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...