Related Experiment Video
Updated: Nov 7, 2025

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Accidental adrenaline auto-injector-induced digital ischaemia: a proposed treatment algorithm
Elizabeth Rajiah1, Andrew R McKean2, Charles Bain2
1Plastic Surgery, Saint Thomas' Hospital, London, UK elizabeth.rajiah@doctors.org.uk.
Abstract:
Increased numbers of adrenaline auto-injectors (AAIs) are in circulation in the UK. The rate of accidental auto-injection injuries has increased during this time. Various treatment strategies are described in the literature. We present the case of a 32-year-old, right-hand-dominant man who sustained an unintentional AAI injury to the volar aspect of his right thumb. On presentation to the emergency department, the thumb was ischaemic. There was no improvement with simple conservative measures (warm soaks). The patient was referred to our tertiary hand surgery service and a digital block using 2% lidocaine promoted reversal of ischaemia within 2 hours with no long-term sequelae. Phentolamine rescue, on standby, was not necessary in this case. In this case report, we highlight the therapeutic challenges associated with managing AAI injury and propose an evidence-based treatment algorithm to prevent risk of severe adverse outcomes such as digital necrosis.
Related Concept Videos
Acute Coronary Syndrome IV: Interprofessional Care
Cardiopulmonary Resuscitation IV: Pharmacological Management
Angina IV: Management
Acute Coronary Syndrome I: Introduction
Coronary Artery Disease V: Interprofessional Care
Angina V: Nursing Management