Related Experiment Video
Updated: Nov 7, 2025

07:55
Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
11.2K
Correction to "High Selectivities among Monovalent Cations in Dialysis through Cation-Exchange Membranes Coated with
ACS Applied Materials & Interfaces
|April 29, 2021
Summary
No abstract available in PubMed .
More Related Videos
Related Concept Videos
Ion Exchange
779
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
779
Dialysis
1.1K
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
1.1K
Ion-Exchange Chromatography
1.1K
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
1.1K
Potentiometry: Membrane Electrodes
1.1K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.1K
EDTA: Chemistry and Properties
2.5K
Polydentate ligands are most widely used in complexometric titrations because they form more stable complexes with the metal ions than mono- or bidentate ligands due to the chelate effect. Examples of polydentate ligands are ethylenediaminetetraacetic acid (EDTA), crown ethers, and cryptands. The most important feature of optimal polydentate ligands is the ability to form 1:1 complexes in a single-step process. Amino carboxylic acid derivatives are frequently used as complexing agents. EDTA is...
2.5K
Masking and Demasking Agents
3.0K
EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
3.0K