pH Dependence of T2 for Hyperpolarizable 13C-Labelled Small Molecules Enables Spatially Resolved pH Measurement by

Martin Grashei1, Christian Hundshammer1, Frits H A van Heijster1

  • 1Department of Nuclear Medicine, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, D-81675 Munich, Germany.

Related Concept Videos

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.3K
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
1.0K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
8.3K
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
708
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.3K
NMR Spectroscopy: Chemical Shift Overview01:15

NMR Spectroscopy: Chemical Shift Overview

The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
2.6K