Quantitative and Qualitative Running Gait Analysis through an Innovative Video-Based Approach
Laura Simoni1,2, Alessandra Scarton3, Claudio Macchi2
1Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, 37129 Verona, Italy.
Sensors (Basel, Switzerland)
|April 30, 2021
Summary
Graal software offers a valid and cost-efficient method for quantitative running gait analysis, accurately measuring cadence and step length. However, its effectiveness for qualitative gait analysis requires further research.
Area of Science:
- Biomechanics
- Sports Science
- Motion Analysis
Background:
- Running gait analysis is crucial for identifying and monitoring gait abnormalities linked to running injuries.
- Marker-less video sensor technology offers a potentially time- and cost-efficient alternative to traditional methods.
- The Graal system, previously validated for walking, was optimized for running gait analysis.
Purpose of the Study:
- To validate an improved version of the Graal video analysis software for quantitative and qualitative running gait analysis.
- To compare Graal's measurements against a gold-standard photosensor system (Optogait).
Main Methods:
- 33 healthy recreational runners performed treadmill running at a self-selected speed.
- Simultaneous data collection using the optimized Graal system and the Optogait photosensor system.
- Graal software analyzed pixel brightness variations to determine gait frequencies (F1, F2), step length, harmony, and synchrony.
- Optogait measured step length, cadence, and variability (vCAD).
Main Results:
- Graal's F2 measurement showed high correlation (r² = 0.81) and no significant difference with Optogait's cadence.
- Graal's step length measurement demonstrated a very high correlation (r² = 0.98) and no significant difference with Optogait's step length.
- Bland-Altman analysis confirmed minimal bias and imprecision between Graal and Optogait for quantitative measures.
- No significant correlation was found between Optogait's vCAD and Graal's harmony or synchrony indices.
Conclusions:
- The optimized Graal system is a valid and cost-efficient tool for quantitative running gait analysis.
- Graal accurately measures cadence and step length, comparable to the Optogait system.
- The validity of Graal for qualitative running gait analysis remains inconclusive and needs further investigation across various running intensities.