Related Experiment Video
Updated: Nov 7, 2025
![Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62334.jpg&w=3840&q=50)
Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
[18F]fluoro-ethylcholine-PET Plus 4D-CT (FEC-PET-CT): A Break-Through Tool to Localize the "Negative" Parathyroid
Constantin Smaxwil1, Philip Aschoff2, Gerald Reischl3,4
1Department of Endocrine Surgery, Endokrines Zentrum Stuttgart, Diakonie-Klinikum Stuttgart, 70176 Stuttgart, Germany.
Background:
The diagnostic performance of [18F]fluoro-ethylcholine-PET-CT&4D-CT (FEC-PET&4D-CT) to identify parathyroid adenomas (PA) was analyzed when ultrasound (US) or MIBI-Scan (MS) failed to localize. Postsurgical one year follow-up data are presented.
Methods:
Patients in whom US and MS delivered either incongruent or entirely negative findings were subjected to FEC-PET&4D-CT and cases from July 2017 to June 2020 were analyzed, retrospectively. Cervical exploration with intraoperative PTH-monitoring (IO-PTH) was performed. Imaging results were correlated to intraoperative findings, and short term and one year postoperative follow-up data.
Results:
From July 2017 to June 2020 in 171 FEC-PET&4D-CTs 159 (92.9%) PAs were suggested. 147 patients already had surgery, FEC-PET&4D-CT accurately localized in 141; false neg. 4, false pos. 2, global sensitivity 0.97; accuracy 0.96, PPV 0.99. All of the 117 patients that already have completed their 12-month postoperative follow up had normal biochemical parameter, i.e., no signs of persisting disease. However, two cases may have a potential for recurrent disease, for a cure rate of at least 98.3%.
Conclusion:
FEC-PET&4D-CT shows unprecedented results regarding the accuracy localizing PAs. The one-year-follow-up data demonstrate a high cure rate. We, therefore, suggest FEC-PET-CT as the relevant diagnostic tool for the localization of PAs when US fails to localize PA, especially after previous surgery to the neck.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET