Clinical performance of a machine-learning algorithm to predict intra-operative hypotension with noninvasive arterial
Marije Wijnberge1, Björn J P van der Ster, Bart F Geerts
1From the Department of Anaesthesiology (MW, BvdS, BFG, FdB, CB, DE, MWH, DPV) and Department of Intensive Care, Amsterdam UMC, location AMC, Amsterdam, The Netherlands (APJV).
Background:
Intra-operative hypotension is associated with adverse postoperative outcomes. A machine-learning-derived algorithm developed to predict hypotension based on arterial blood pressure (ABP) waveforms significantly reduced intra-operative hypotension. The algorithm calculates the likelihood of hypotension occurring within minutes, expressed as the Hypotension Prediction Index (HPI) which ranges from 0 to 100. Currently, HPI is only available for patients monitored with invasive ABP, which is restricted to high-risk procedures and patients. In this study, the performance of HPI, employing noninvasive continuous ABP measurements, is assessed.
Objectives:
The first aim was to compare the performance of the HPI algorithm, using noninvasive versus invasive ABP measurements, at a mathematically optimal HPI alarm threshold (Youden index). The second aim was to assess the performance of the algorithm using a HPI alarm threshold of 85 that is currently used in clinical trials. Hypotension was defined as a mean arterial pressure (MAP) below 65 mmHg for at least 1 min. The predictive performance of the algorithm at different HPI alarm thresholds (75 and 95) was studied.
Design:
Observational cohort study.
Setting:
Tertiary academic medical centre.
Patients:
Five hundred and seven adult patients undergoing general surgery.
Results:
The performance of the algorithm with invasive and noninvasive ABP input was similar. A HPI alarm threshold of 85 showed a median [IQR] time from alarm to hypotension of 2.7 [1.0 to 7.0] min with a sensitivity of 92.7 (95% confidence interval [CI], 91.2 to 94.3), specificity of 87.6 (95% CI, 86.2 to 89.0), positive predictive value of 79.9 (95% CI, 77.7 to 82.1) and negative predictive value of 95.8 (95% CI, 94.9 to 96.7). A HPI alarm threshold of 75 provided a lower positive predictive value but a prolonged time from prediction to actual hypotension.
Conclusion:
This study demonstrated that the algorithm can be employed using continuous noninvasive ABP waveforms. This opens up the potential to predict and prevent hypotension in a larger patient population.
Trial Registration:
Clinical trials registration number NCT03533205.
More Related Videos
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure