Related Experiment Video
Updated: Nov 6, 2025

Tools for Surface Treatment of Silicon Planar Intracortical Microelectrodes
Published on: June 8, 2022
Zwitterionic polydopamine coatings suppress silicone implant-induced capsule formation
Chung Min Shin1, Soojeong Cho2, Dong Ho Kim3
1Department of Plastic and Reconstructive Surgery, Chungnam National University College of Medicine, Daejeon 35015, Republic of Korea. djplastic@cnu.ac.kr.
Abstract:
A synthetic zwitterionic dopamine derivative (ZW-DOPA) containing both catechol and amine groups was recently shown to exhibit excellent antifouling activity on marine surfaces. Here, we have extended these analyses to investigate the effects of ZW-DOPA coating on silicone implants. Successful formation of ZW-DOPA coatings on silicone implants was confirmed based on a combination of decreased static water contact angles on silicone implants, evidence of new peaks at 400.2 (N 1s), 232.2 (S 2s), and 168.0 (S 2p) eV, and increased quantitative atomic composition of C 1s with a concurrent decrease of Si 2p. Anti-biofilm formation assays revealed that ZW-DOPA coating prevented biofilm formation on silicone at a non-lethal concentration (0.5 mg mL-1). Capsule formation was also significantly inhibited by ZW-DOPA coating in vivo and the differentiation of fibroblasts into myofibroblasts was significantly suppressed. Together, these data suggest that silicone implants coated with ZW-DOPA may prevent capsular contracture after insertion when used in breast surgery.