Influences of oxidation ability on precision in nitrogen isotope measurements of organic reference materials using
Nan Wang1,2, Jingyu Liu2,3, Yang Zhang1,2
1Frontiers Science Center for Deep Ocean Multispheres and Earth System, Key Lab of Submarine Geosciences and Prospecting Techniques, MOE and College of Marine Geosciences, Ocean University of China, Qingdao, 266100, China.
Rationale:
The precision of the standard measurements of reference materials (RMs) is critical to normalize the raw δ15 N values of samples to the international scale. Because the measurement configuration is required to moderate the properties of both RMs and samples for obtaining an ideal measurement precision, it is important to determine the appropriate measurement configurations of RMs to achieve accurate nitrogen isotope compositions of samples. Therefore, it is critical to systematically examine RMs for optimizing the configurations and further improve the measurement precision.
Methods:
Gas source isotope ratio mass spectrometry (IRMS) coupled with an online elemental analyzer (EA) equipped with a single-quartz reactor was performed to analyze the nitrogen isotope compositions. Some adjustments were made as follows: (a) as the in-house working standard, urea was used to investigate the influences of combustion through moderating the different oxygen injections (0-20 mL) and sample delay times (10-12 s) and optimize the combustion conditions to enhance oxidation ability; (b) CO2 from the sample gas stream was removed to prevent interferences between CO2 and N2 ; (c) international RMs, including USGS40 (l-glutamic), IAEA600 (caffeine), and soil standard (B2153) with a low organic content, were systematically analyzed under the optimized configurations, and the precisions of the δ15 N values were further examined.
Results:
Our results showed that sufficient oxygen should be injected to improve the sample combustion when analyzing δ15 N in natural samples such as soil or marine sediment with low organic content. In addition, the measurement precision of δ15 N was affected by the tailing of the CO2 peak from the gas chromatography column into the subsequent sample measurement if the EA is equipped with a single-quartz reactor column. Our adjustments can produce an optimized repeatability and accuracy of the δ15 N value, especially for RMs with low organic content, and the uncertainty of the measurements is improved to be better than 0.1‰ under optimized configurations.
Conclusions:
The analytical conditions such as the oxygen flow rate and injection time or sample introduction time into the EA need to be adjusted depending on the combustion conditions of the RMs and samples to obtain a reliable accuracy of measurement. We recommend that when analyzing δ15 N of natural samples such as soil or marine sediment samples with low organic content, more oxygen should be injected to improve the combustion of the samples. In addition, CO2 should be removed from the sample gas stream before being introduced into the isotope ratio mass spectrometer when the EA is equipped with a single-quartz reactor.
More Related Videos
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Propagation of Uncertainty from Systematic Error
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Mass Spectrum: Interpretation
To...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...