Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Scout-based Multi-Echo NAvigator (SMENA) for high temporal resolution motion and B <sub>0</sub> estimation and correction: applications to multi-echo GRE and EPTI.

bioRxiv : the preprint server for biology·2026
Same author

Multiphasic myelination and dendritic growth modulate qMRI signals in human visual cortex.

bioRxiv : the preprint server for biology·2026
Same author

Time-Conditioned Zero-Shot Self-Supervised Reconstruction for Accelerated 3D Ultra-Low-Field MRI.

Magnetic resonance in medicine·2026
Same author

Semi-supervision for clinical contrast-weighted image synthesis from magnetic resonance fingerprinting.

Magma (New York, N.Y.)·2026
Same author

Accelerating MRI With Longitudinally-Informed Latent Posterior Sampling.

Magnetic resonance in medicine·2026
Same author

A Dynamic Shim Approach for Correcting Eddy Current Effects in Diffusion-Prepared MRI Acquisition Using a Multi-Coil AC/DC Shim-Array.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
Same journal

Prospective Head Motion Correction in T1- and T2-Weighted Long Echo Train Sequences Using Servo Navigation.

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: Nov 6, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.4K

Segmented simultaneous multi-slice diffusion-weighted imaging with navigated 3D rigid motion correction.

Malte Riedel Né Steinhoff1, Kawin Setsompop2,3,4, Alfred Mertins1

  • 1Institute for Signal Processing, University of Luebeck, Luebeck, Germany.

Magnetic Resonance in Medicine
|May 6, 2021
PubMed
Summary
This summary is machine-generated.

This study presents a new image reconstruction method to fix motion artifacts in brain scans. By using special low-resolution data trackers, the technique corrects for head movement during complex MRI procedures. This approach improves image clarity and reliability for clinical diagnostics.

Keywords:
EPIbrainfull-volume reconstructionmodel-based image reconstructionmotion correctionmulti-shot DWIMRI reconstructionmotion artifactsdiffusion tensor imagingimage processing algorithms

Frequently Asked Questions

More Related Videos

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.5K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

22.8K

Related Experiment Videos

Last Updated: Nov 6, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.4K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.5K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

22.8K

Area of Science:

  • Medical imaging physics research within Segmented simultaneous multi-slice diffusion-weighted imaging
  • Radiological science and diagnostic instrumentation

Background:

No prior work had fully resolved the challenge of rigid motion artifacts in segmented simultaneous multi-slice diffusion-weighted imaging. Standard echo-planar imaging techniques often suffer from significant signal degradation when subjects move during acquisition. That uncertainty drove the need for robust correction strategies that address both in-plane and through-plane displacements. Previous reconstruction approaches lacked the ability to integrate shot-specific phase information with comprehensive spatial motion parameters. This gap motivated the development of advanced algorithms capable of handling complex data corruption. Researchers have long sought to maintain high fidelity in diffusion tensor measurements despite inevitable patient movement. Existing methods frequently failed to account for the interplay between multi-slice acceleration and dynamic head positioning. That limitation hindered the widespread adoption of accelerated scanning protocols in clinical environments.

Purpose Of The Study:

The primary aim of this study is to improve the robustness of diffusion-weighted imaging data against in-plane and through-plane rigid motion. Researchers sought to address the significant signal degradation that occurs during segmented simultaneous multi-slice echo-planar imaging. This gap motivated the development of a novel algorithm that incorporates 3D rigid motion correction. The team intended to integrate wavelet denoising into the image reconstruction process to further enhance clarity. They aimed to utilize low-resolution navigators to accurately estimate shot-specific diffusion phase corruptions. The study sought to demonstrate the feasibility of retrospective motion correction for complex diffusion datasets. Investigators also intended to validate the performance of their method through both simulations and in vivo experiments. That uncertainty drove the need for a robust solution that could handle rapid head displacements during clinical scanning.

Main Methods:

The review approach involved developing a reconstruction framework that incorporates 3D rigid motion correction and wavelet denoising. Investigators utilized low-resolution navigators to estimate shot-specific diffusion phase corruptions. The team performed SMS-to-volume registration to derive precise motion parameters for each diffusion direction. These parameters were then integrated into a SENSE-based full-volume reconstruction pipeline. The researchers evaluated the algorithm using both simulated datasets and in vivo experiments. They compared their proposed method against a navigated SMS reconstruction that lacked gross motion correction. Four-fold interleaved 3-SMS diffusion tensor acquisitions served as the primary data source for validation. The study design focused on demonstrating the feasibility of retrospective correction for complex diffusion-weighted datasets.

Main Results:

The strongest finding indicates that the proposed algorithm achieves submillimeter registration errors during the SMS-to-volume process. Simulations confirmed that this approach significantly improves image reconstruction quality compared to standard navigated SMS methods. In vivo experiments validated successful artifact reduction in scans compromised by 3D motion. The system demonstrated a temporal motion resolution of approximately 0.3 seconds during these trials. High fidelity was consistently maintained throughout the registration phase of the reconstruction. The results show that the integration of shot-specific parameters effectively mitigates signal corruption. Quantitative analysis revealed that the new method outperforms traditional reconstruction techniques in motion-prone scenarios. These findings confirm the efficacy of retrospective correction for segmented multi-slice diffusion-weighted imaging.

Conclusions:

The authors propose that their integrated reconstruction framework effectively mitigates motion-related signal loss in diffusion scans. This synthesis suggests that shot-specific navigators provide sufficient information to estimate complex 3D rigid transformations. Their findings imply that retrospective correction improves the overall diagnostic quality of accelerated imaging datasets. The researchers conclude that submillimeter registration accuracy is achievable through their novel registration approach. This work demonstrates that combining wavelet denoising with motion estimation enhances the robustness of the final images. The study indicates that temporal resolution of approximately 0.3 seconds is sufficient for capturing rapid head displacements. These implications suggest a pathway for more reliable diffusion-weighted imaging in motion-prone populations. The authors maintain that their method represents a viable solution for overcoming limitations inherent to segmented multi-slice acquisition schemes.

The researchers propose an algorithm integrating 3D rigid motion correction and wavelet denoising into the reconstruction process. This mechanism utilizes low-resolution navigators to estimate shot-specific diffusion phase corruptions and motion parameters through SMS-to-volume registration, unlike standard methods that lack gross motion compensation.

The study employs low-resolution navigators to capture shot-specific data. These components facilitate the estimation of diffusion phase corruptions and 3D rigid motion parameters, which are then integrated into a SENSE-based full-volume reconstruction, contrasting with conventional SMS-only approaches.

The authors note that SMS-to-volume registration is necessary to accurately map shot-wise motion parameters. This technical requirement allows the system to align individual slices into a coherent 3D volume, whereas non-navigated reconstructions fail to resolve through-plane displacement.

Shot-specific navigators serve as the primary data source for estimating motion. These inputs allow the algorithm to perform retrospective corrections, whereas traditional techniques rely on prospective gating or lack correction entirely.

The researchers measured registration errors at submillimeter levels. This performance metric confirms the high fidelity of the registration process, which is superior to the performance of navigated SMS reconstructions without gross motion correction.

The authors propose that their method enables reliable diffusion-weighted imaging in motion-compromised scans. They suggest this approach facilitates the use of accelerated protocols, unlike previous methods that were limited by sensitivity to patient movement.