Related Experiment Video
Updated: Nov 6, 2025

Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Development and optimization of hot-melt extruded moxifloxacin hydrochloride inserts, for ocular applications, using
Ruchi Thakkar1, Neeraja Komanduri1, Narendar Dudhipala1
1Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; Research Institute of Pharmaceutical Sciences, University of Mississippi, University, MS 38677, USA.
Abstract:
The current study sought to formulate sustained-release hot-melt extruded (HME) ocular inserts of moxifloxacin hydrochloride (MOX; MOX-HME) for the treatment of bacterial keratitis. The concentration of Eudragit™ FS-100 (FS) and propylene glycol (PG) used as polymer and plasticizer, respectively, in the inserts were optimized using the central composite design (CCD) to achieve sustained release. The inserts were characterized for weight, thickness, surface characteristics, pH, and in vitro release profile. The crystalline characteristics of MOX and surface morphology of the inserts were evaluated using differential scanning calorimetry (DSC) and scanning electron microscopy (SEM). Furthermore, ex vivo permeation through rabbit cornea and stability of the optimized MOX-HME insert was investigated. The results demonstrate an inverse correlation between FS concentration and MOX release from the MOX-HME inserts, and a potential 24 h release. The optimized MOX-HME inserts were found to be stable at room temperature for four months, showing no significant change in drug content, pH and release profile. MOX converted into an amorphous form in the MOX-HME inserts and did not recrystallize during the study period. SEM analysis confirmed the smooth surface of the MOX-HME insert. The ex vivo studies revealed that the MOX-HME inserts provided a much prolonged transcorneal MOX flux as compared to the commercial ophthalmic solution and the immediate-release MOX-HME insert. The results indicate that MOX-HME inserts could potentially provide a once-a-day application, consequently reducing the dosing frequency and acting as an alternative delivery system in the management of bacterial infections.
More Related Videos
08:38Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications
Published on: January 16, 2018
07:12Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
Published on: September 27, 2021