Related Experiment Video
Updated: Apr 23, 2026

Knowledge Based Cloud FE Simulation of Sheet Metal Forming Processes
Published on: December 13, 2016
Mechanistic prediction of powder flowability through Bond number: Model calibration and estimation of flow
Siddharth Tripathi1, Anna Owasit1, Christopher Kossor1
1New Jersey Center for Engineered Particulates, New Jersey Institute of Technology, Newark, NJ 07102, USA.
Abstract:
The granular Bond number, estimated using Chen's multi-asperity particle adhesion model, has been shown as a basis for powder flowability prediction for both as-received and dry-coated powders. Here, the prediction model calibrated solely using as-received powders is tested by estimating the expected flowability enhancement after dry coating with two different nano-silicas. Prediction accuracy for 9 APIs and 18 excipients is compared for three characteristic particle size parameters for the Bond number; median particle size (d50), Sauter mean diameter (d3,2), and the size class-dependent (SCD) metric utilizing entire particle size distribution (PSD). A new sigmoid-function based flowability prediction model is proposed and fitted for as-received powders. Both d3,2 and SCD lead to better predictive accuracy with narrower prediction intervals as compared to d50, suggesting d3,2 captures the same surface-area-dependent PSD effects as SCD without added computational burden. The model could accurately predict flow category for all but one as-received powder. The model calibrated through as-received uncoated powders can predict enhancement of one to three flow categories for most dry coated powders with high accuracy. Notable exceptions are materials with SSA above ∼2 m2/g whose experimental SSA deviates significantly from PSD-estimated theoretical SSA (high ΔSSA), indicating surface roughness or adherent debris that restricts dry coating effectiveness. Materials with high SSA but low ΔSSA, where high surface area is simply a consequence of fine particle size, respond well to dry coating as predicted. In summary, the proposed unifying model can be calibrated using small samples of as-received powders to estimate expected flowability improvements after dry coating and, importantly, to identify dry coated powders likely to underperform.
Related Concept Videos
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Typical Model Studies
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Compendial Testing Models II
Pipe Flowrate Measurement: Problem Solving

