Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
A cuboid chromatography device having short bed-height gives better protein separation at a significantly lower
Guoqiang Chen1, Roxana Roshankhah1, Raja Ghosh1
1Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada.
Abstract:
Simultaneously reducing the bed-height and increasing the area of cross-section, while keeping the bed-volume the same, would substantially reduce the pressure drop across a process chromatography column. This would minimize problems such as resin compaction and non-uniformity in column packing, which are commonly faced when using soft chromatographic media. However, the increase in macroscale convective dispersion due to the increase in column diameter, and the resultant loss in resolution would far outweigh any potential benefit. Cuboid-packed bed devices have lower macroscale convective dispersion compared to their equivalent cylindrical columns. In this paper, we discuss how and why a flat cuboid chromatography device having a short bed-height gives better protein separation, at a significantly lower pressure drop, than a taller column having the same bed-volume. First, we explored this option based on computational fluid dynamic (CFD) simulations. Depending on the flow rate, the pressure drop across the flat cuboid device was lower than that in the tall column by a factor of 6.35 to 6.4 (i.e. less than 1/6th the pressure). The CFD results also confirmed that the macroscale convective dispersion within the flat cuboid device was significantly lower. Head-to-head separation experiments using a 1 mL flat cuboid device having a bed-height of 10 mm, and a 1 mL tall column having a bed-height of 25.8 mm, both packed with the same chromatographic media, were carried out. The number of theoretical plates per unit bed-height was on an average, around 2.5 time times greater with the flat cuboid device, while the total number of theoretical plates in the two devices were comparable. At any given superficial velocity, the height equivalent of a theoretical plate in the tall column was on an average, higher by a factor 2.5. Binary protein separation experiments showed that at any given flow rate, the resolution obtained using the flat cuboid device was significantly higher than that obtained with the tall column. This work opens up the possibility of designing and developing short bed-height chromatography devices for carrying out high-resolution biopharmaceutical purifications, at very low pressures.
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...