Related Experiment Video
Updated: Nov 6, 2025

Homogeneous Time-resolved Förster Resonance Energy Transfer-based Assay for Detection of Insulin Secretion
Published on: May 10, 2018
AI powered electrochemical multi-component detection of insulin and glucose in serum
Yuliang Zhao1, Hongyu Zhang1, Yang Li2
1School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China.
Abstract:
Multi-component detection of insulin and glucose in serum is of great importance and urgently needed in clinical diagnosis and treatment due to its economy and practicability. However, insulin and glucose can hardly be determined by traditional electrochemical detection methods. Their mixed oxidation currents and rare involvement in the reaction process make it difficult to decouple them. In this study, AI algorithms are introduced to power the electrochemical method to conquer this problem. First, the current curves of insulin, glucose, and their mixed solution are obtained using cyclic voltammetry. Then, seven features of the cyclic voltammetry curve are extracted as characteristic values for detecting the concentrations of insulin and glucose. Finally, after training using machine learning algorithms, insulin and glucose concentrations are decoupled and regressed accurately. The entire detection process only takes three minutes. It can detect insulin at the pmol level and glucose at the mmol level, which meets the basic clinical requirements. The average relative error in predicting insulin concentrations is around 6.515%, and that in predicting glucose concentrations is around 4.36%. To verify the performance and effectiveness of the proposed method, it is used to determine the concentrations of insulin and glucose in fetal bovine serum and real clinical serum samples. The results are satisfactory, demonstrating that the method can meet basic clinical needs. This multi-component testing system delivers acceptable detect limit and accuracy and has the merits of low cost and high efficiency, holding great potential for use in clinical diagnosis.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020
Related Concept Videos
Amperometry: Overview
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...