Related Experiment Video
Updated: Nov 6, 2025

Microfluidic Production of Lysolipid-Containing Temperature-Sensitive Liposomes
Published on: March 3, 2020
Impact of Different Mixing Methods on the Performance of Suspension-Based Transdermal Delivery Systems
Sonalika Arup Bhattaccharjee1, Madhura Kale1, Ngan Le2
1Center for Drug Delivery Research, Department of Pharmaceutical Sciences, College of Pharmacy, Mercer University, 3001 Mercer University Dr, Atlanta, Georgia, 30341, USA.
Abstract:
Suspension-based matrix transdermal delivery systems (TDSs) are specialized systems that maintain a continuous driving force for drug delivery over prolonged wear. The pressure-sensitive adhesive (PSA) is the most critical constituent of such systems. Our study aimed to determine the effect of different mixing methods on the performance of silicone PSA-based suspension TDSs. Lidocaine suspension TDSs were prepared using conventional slow rotary mixing, high-speed homogenization, bead-mill homogenization, vortex shaking, and by an unguator. Resultant TDSs were tested for tack, shear, and peel properties and correlated to coat weight, content uniformity, microstructure, and in vitro permeation across dermatomed human skin. Every mixing method tested caused a significant reduction in peel. However, bead-mill homogenization resulted in significant loss of all adhesive properties tested, while unguator-mixed TDSs retained most properties. Good linear correlation (R2 = 1.000) between the shear properties of the TDSs with the average cumulative amount of lidocaine permeated after 24 h was observed, with no significant difference between percutaneous delivery from slow rotary-mixed systems (1334 ± 59.21 μg/cm2) and unguator-mixed systems (1147 ± 108.3 μg/cm2). However, significantly lower delivery from bead-mill homogenized systems (821.1 ± 28.00 μg/cm2) was noted. While many factors affect TDS performance, careful consideration must also be given to the processing parameters during development as they have been shown to affect the resultant system's therapeutic efficacy. Extensive mixing with bead-mill homogenization demonstrated crystallization of drug, loss in adhesive properties, coat weight, and film thickness, with reduced transdermal delivery of lidocaine from the prepared system.
More Related Videos
Related Concept Videos
Factors Influencing Drug Absorption: Pharmaceutical Parameters
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Dissolution: Alternative Methods
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry
Drug Delivery: Overview
Enteral delivery involves administering drugs directly through swallowing, sublingual placement, or buccal application. Orally administered drugs predominantly navigate the...

