Related Experiment Video
Updated: Nov 5, 2025

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Implant malposition and revision surgery in primary orbital fracture reconstructions
Matti Nikunen1, Hanna Rajantie1, Emilia Marttila1
1Department of Oral and Maxillofacial Diseases, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
Abstract:
The aim of the study was to assess factors leading to revision surgery and implant position of primary orbital fracture reconstructions. A retrospective cohort included patients who underwent orbital floor and/or medial wall fracture reconstruction for recent trauma. Demographics, fracture type, surgery and implant-related variables, and postoperative implant position were analyzed. The overall revision surgery rate was 6.5% (15 of 232 surgeries). The rate was highest in combined midfacial fractures with rim involvement (14.0%), lower in zygomatico-orbital fractures (8.7%), and lowest in isolated blowout fractures (3.8%). Fracture type, orbital rim fixation and implant malposition predicted revision. The best positioning was achieved with patient-specific milled titanium implants (mtPSI) and resorbable materials, whereas the poorest with preformed three-dimensional titanium plates. Combined midfacial fractures with rim involvement in particular have a high risk for orbital revision surgery. Within the limitations of the present study, mtPSIs should be preferred in the reconstruction of primary orbital fractures if possible.