Related Experiment Video
Updated: Nov 5, 2025

Examination of Rapid Dopamine Dynamics with Fast Scan Cyclic Voltammetry During Intra-oral Tastant Administration in Awake Rats
Published on: August 12, 2015
Lithium cobalt phosphate electrode for the simultaneous determination of ascorbic acid, dopamine, and serum uric acid
Yanxue Xu1, Zirui Meng2, Yan Meng3
1Institute of Advanced Study, Chengdu University, No. 2025, Chengluo Avenue, Chengdu, People's Republic of China.
Abstract:
Lithium cobalt phosphate (LCP) was prepared and modified on the surface of glassy carbon electrode (GCE) to fabricate the electrochemical sensor (LCP/GCE) for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and serum uric acid (UA). The homogenous incorporation of carbon improved the conductivity of LCP. Benefiting from the small particle size distribution, LCP/GCE has a large active surface and responds to AA, DA, and UA sensitively and rapidly. For the simultaneous detection with differential pulse voltammetry the anodic peaks of AA, DA, and UA were well-separated and appeared at ~0 V, ~0.19 V, and ~ 0.33 V (vs. Ag/AgCl), respectively. The linear responses toward AA, DA, and UA were in the range 10 μM-8.0 mM, 10 nM-10 μM, and 0.020 μM-25 μM; the detection limits were estimated to be 8.10 μM, 7.50 nM, and 22.7 nM (S/N = 3), respectively. The excellent selectivity and reproducibility of LCP/GCE enable serum UA to be detected without the interference of AA and DA. The recoveries of DA and AA in the serum sample were in the range 95 to 111%. The results indicate that LCP has the potential to be developed as the sensing devices to be applied to in vitro diagnosis. The lithium-ion battery cathodic material, LCP with the excellent adsorption and catalytic behavior, was utilized to fabricate the electrochemical sensor for the sensitive and simultaneous detection of AA, DA, and UA, which achieved the low detection limits and the wide concentration ranges. LCP/GCE can be used for the quantitative detection of serum UA without the interference of DA and AA. In addition, the recoveries of DA and AA in human serum were satisfactory, which illustrate the reliability of LCP/GCE to be applied to in vitro diagnosis.
More Related Videos
Related Concept Videos
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...