Residual solvent analysis with hyper-fast gas chromatography-mass spectrometry and a liquid carbon dioxide
Miriam D Chopra1, Peter J Müller2, Jan Leppert1
1Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch Allee 5, Bonn D-53115, Germany.
Abstract:
A new hyper-fast gas chromatography method with less than 90 s runtime including the column cool down was developed for the analysis of four gases and 16 residual solvents, combining a CO2 cryofocusing with a flow-field thermal gradient gas chromatograph (FF-TG-GC) and ToF-MS. The extremely low analysis time can be achieved by combining the new FF-TG-GC and a very short Rxi-624 Sil MS separation column with a small inner diameter and small film thickness (2.05 m × 0.1 mm × 1.0 µm). The column is inserted into a low thermal mass, resistively heated stainless steel capillary. This enables fast temperature programs with heating rates up to 3000 °C/min and a column cool down within a few seconds. In addition to temporal temperature gradients, the FF-TG-GC can generate a spatial temperature gradient that leads to an improved peak shape. Further, an external liquid CO2 cryo-trap was designed in order to reduce the injection bandwidths of analytes and to take full advantage of the resolving power of the separation column. No modifications are required to the FF-TG-GC for the use of the cryogenic trap, as the cooled spot is heated by the resistively heated stainless steel capillary during the temperature program. With cryofocusing, analyzed residual solvents are baseline separated. R2 values over 0.99 for calibration curves and low relative standard deviations (mainly < 3%) for repeatability tests were obtained.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
