Related Experiment Video
Updated: Nov 5, 2025

Athymic Rat Model for Evaluation of Engineered Anterior Cruciate Ligament Grafts
Published on: March 26, 2015
Computed Tomography Imaging of BioComposite Interference Screw After ACL Reconstruction With Bone-Patellar
Brian Scrivens1, Melissa A Kluczynski1, Marc S Fineberg1
1Department of Orthopaedics, Jacobs School of Medicine and Biomedical Science, The State University of New York at Buffalo, Buffalo, New York, USA.
Background:
Bioabsorbable interference screws tend to have high resorption rates after anterior cruciate ligament (ACL) reconstruction; however, no studies have examined screws composed of 30% biphasic calcium phosphate and 70% poly-d-lactide (30% BCP/70% PLDLA).
Purpose:
To evaluate femoral and tibial tunnel widening and resorption of 30% BCP/70% PLDLA interference screws and replacement with bone at 2 to 5 years after ACL reconstruction using bone-patellar tendon-bone (BTB) autograft.
Study Design:
Case series; Level of evidence, 4.
Methods:
Included were 20 patients who had undergone ACL reconstruction using BTB autograft and were reevaluated 2 to 5 years after surgery using computed tomography scans. Tunnel measurements were obtained from computed tomography scans in the sagittal and coronal planes and were compared with known tunnel measurements based on operative reports. These images and measurements were used to assess tunnel widening, resorption of the 30% BCP/70% PLDLA screw, its replacement with bone, and possible cyst formation. Paired t tests were used to compare initial and final femoral and tibial tunnel measurements.
Results:
The cross-sectional area of the femoral tunnel decreased at the aperture (P = .03), middle (P = .0002), and exit (P < .0001) of the tunnel compared with the initial femoral tunnel size, and the tibial tunnel cross-sectional area decreased at the aperture (P < .0001) and exit (P = .01) of the tunnel compared with the initial tibial tunnel size. Bone formation was observed in 100% of femoral tunnels and 94.7% of tibial tunnels. Screw resorption was 100% in the femur and 94.7% in the tibia at the final follow-up. Cysts were noted around the femoral tunnel in 2 patients (5.1%).
Conclusion:
The 30% BCP/70% PLDLA interference screws used for ACL reconstruction using BTB autograft had high rates of resorption and replacement with bone, and there were no increases in tunnel size at 2 to 5 years postoperatively. The authors observed a low rate of cyst formation and no other adverse events stemming from the use of this specific biointerference screw, suggesting that this type of screw is a reasonable option for graft fixation with minimal unfavorable events and a reliable resorption profile.
More Related Videos
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
06:27Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
Published on: September 29, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography