Related Experiment Video
Updated: Nov 5, 2025

Glaucoma-inducing Procedure in an In Vivo Rat Model and Whole-mount Retina Preparation
Published on: March 12, 2016
Comparison of Topical Instillation From Single-dose and Multidose Eye Drop Containers in Glaucoma: A Multicenter
Florent Aptel1,2, Anne-Sophie Villemont3,4, Pierre Cunnac1,2
1Department of Ophthalmology, Hôpital Michallon, Grenoble.
Precis:
We compared the quality of instillation of topical treatments from single-dose (SGD) or multidose (MTD) containers in glaucoma patients and showed neither a significant difference between the type of container nor a significant relationship to upper limb mobility.
Purpose:
To describe and compare the quality of instillation of topical treatments with SGD or MTD containers in glaucoma patients. To assess factors likely to influence instillation, particularly the upper limb mobility.
Materials And Methods:
This multicenter, cross-sectional study included open-angle glaucoma patients with the same self-instilled treatment over at least 3 months. Patients were asked to successively self-administer a drop of artificial tears from SGD and MTD containers in front of an observer. The order of instillation (eye and container) was randomized. Correct instillation was defined as the administration of 1 drop in the lower fornix, without any contact between the tip of the device and the ocular surface. The Quick Disabilities of the Arm, Shoulder, and Hand self-questionnaire assessed upper limb mobility.
Results:
A total of 239 eyes from 173 patients were included. For the worst eye group 33% of patients performed correct instillation with MTD versus 32% using SGD (P=1). In the best eye group, 31.7% patients performed a correct instillation with MTD administration versus 27.5% with SGD (P=0.327). Multivariate analysis showed a significant association between an inadequate SGD instillation, old age (P=0.021), the severity of the visual field deficits (P=0.035), and a low quality of life score (P=0.028). No association existed between the Quick Disabilities of the Arm, Shoulder, and Hand score and the quality of instillation.
Conclusions:
These results suggest that the handling of single-use containers should be practiced by patients and evaluated by physicians, especially for the elderly population and those with advanced glaucoma. No difference in instillation quality was found between SGD and MTD.