Related Experiment Video
Updated: Nov 5, 2025

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Prediction of Extubation Failure in COVID-19
Pedro H de Andrade Filho1,2, Eduardo S de Assis Brasil1, Ladyer G Costa1
1Anesthesiology Department, São Paulo- Hospital do Servidor Publico Estadual, São Paulo, Brazil.
Background:
[Formula: see text] may be a reliable noninvasive alternative to the [Formula: see text] index. Furthermore, the ROX index (ie, the ratio of [Formula: see text] to breathing frequency) has been validated to predict high-flow nasal cannula failure in subjects under spontaneous breathing. However, these indices have not been tested in subjects with COVID-19 receiving invasive mechanical ventilation. This study aims to verify the correlation between both the ROX index and [Formula: see text] with [Formula: see text] and the ratio of [Formula: see text] to breathing frequency, and to determine the accuracy of the indices that use [Formula: see text] for the prediction of extubation failure in subjects with COVID-19.
Methods:
A prospective cohort study was conducted from May 15, 2020, to June 15, 2020, with subjects with COVID-19 on invasive mechanical ventilation. Indices using [Formula: see text] in the formula were compared to those using [Formula: see text]. Additionally, the performance of the indices in predicting extubation failure was evaluated.
Results:
This study included 69 subjects age 64.8 ± 14.6 y. There were no differences between the median values of the indices, including between the ROX index and [Formula: see text] to breathing frequency (P = .40) or between [Formula: see text] and [Formula: see text] (P = .83). When comparing the ROX index with the [Formula: see text] index to breathing frequency, they were found to be strongly correlated (R2 = 0.75 [95% CI 0.6763-0.8152], P < .001). The comparison of [Formula: see text] with [Formula: see text] revealed R2 = 0.70 (95% CI 0.563-0.749, P < .001). The area under the receiver operating characteristic curve for the ROX index to determine extubation failure was 0.74 (P = .01), whereas for [Formula: see text] it was 0.78 (P < .001).
Conclusions:
The indices presented a good correlation in subjects with COVID-19 on invasive mechanical ventilation, and both the ROX index and [Formula: see text] can discriminate extubation failure in this population.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...