Comparison of electrochemical impedance spectra for electrolyte-supported solid oxide fuel cells (SOFCs) and protonic

Hirofumi Sumi1, Hiroyuki Shimada2, Yuki Yamaguchi2

  • 1Innovative Functional Materials Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Nagoya, Aichi, 463-8560, Japan. h-sumi@aist.go.jp.

Scientific Reports
|May 20, 2021
PubMed

Related Concept Videos

Batteries and Fuel Cells03:12

Batteries and Fuel Cells

A battery is a galvanic cell that is used as a source of electrical power for specific applications. Modern batteries exist in a multitude of forms to accommodate various applications, from tiny button batteries such as those that power wristwatches to the very large batteries used to supply backup energy to municipal power grids. Some batteries are designed for single-use applications and cannot be recharged (primary cells), while others are based on conveniently reversible cell reactions that...
29.2K
Standard Electrode Potentials03:02

Standard Electrode Potentials

On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
46.6K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1000
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
551
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
1.1K
Ladder Diagrams: Redox Equilibria01:30

Ladder Diagrams: Redox Equilibria

Ladder diagrams are useful tools for understanding redox equilibrium reactions, especially the effects of concentration changes on the electrochemical potential of the reaction. The vertical axis in the redox ladder diagrams represents the electrochemical potential, E. The area of predominance is demarcated using the Nernst equation.
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
585