Objectives:
We attempted to improve the accuracy of coronary CT angiography (CCTA)-derived fractional flow reserve (FFR) (FFRCT) by expanding the coronary tree in the computational fluid dynamics (CFD) domain. An observational study was performed to evaluate the effects of extending the coronary tree analysis for FFRCT from a minimal diameter of 1.2 to 0.8 mm.
Methods:
Patients who underwent CCTA and interventional FFR were enrolled retrospectively. Seventy-six patients qualified based on the inclusion criteria. The three-dimensional (3D) coronary artery tree was reconstructed to generate a finite element mesh for each subject with different lower limits of luminal diameter (1.2 mm and 0.8 mm). Outlet boundary conditions were defined according to Murray's law. The Newton-Krylov-Schwarz (NKS) method was applied to solve the governing equations of CFD to derive FFRCT.
Results:
At the individual patient level, extending the minimal diameter of the coronary tree from 1.2 to 0.8 mm improved the sensitivity of FFRCT by 16.7% (p = 0.022). This led to the conversion of four false-negative cases into true-positive cases. The AUC value of the ROC curve increased from 0.74 to 0.83. Moreover, the NKS method can solve the computational problem of extending the coronary tree to an 0.8-mm luminal diameter in 10.5 min with 2160 processor cores.
Conclusions:
Extending the reconstructed coronary tree to a smaller luminal diameter can considerably improve the sensitivity of FFRCT. The NKS method can achieve favorable computational times for future clinical applications.
Key Points:
• Extending the reconstructed coronary tree to a smaller luminal diameter can considerably improve the sensitivity of FFRCT. • The NKS method applied in our study can effectively reduce the computational time of this process for future clinical applications.
More Related Videos
05:07Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022