Related Experiment Video
Updated: Nov 4, 2025

Recording and Modulation of Epileptiform Activity in Rodent Brain Slices Coupled to Microelectrode Arrays
Published on: May 15, 2018
Exploring the Inhibitory Effect of Low-frequency Magnetic Fields on Epileptiform Discharges in Juvenile Rat
Lei Dong1, Gang Li1, Yang Gao2
1State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China; Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, Tianjin 300072, China.
Abstract:
Stimulation with a low frequency electromagnetic field (LF-EMF) has proven to represent a powerful method for the suppression of seizures, as demonstrated in select clinical and laboratory studies. However, the mechanism by which LF-EMF suppresses seizures remains unclear. The purpose of the present study was to explore the modulatory effect of LF-EMF on epileptiform discharges (EDs) using rat hippocampal slices and investigate the underlying mechanisms that mediate these effects. EDs in hippocampal slices was induced by magnesium-free (zero-Mg2+) artificial cerebrospinal fluid (ACSF) and recorded using an in vitro micro-electrode array (MEA). A small sub-decimeter coil was designed and incorporated in a flexible magnetic stimulation device that allowed electromagnetic fields with different parameters to be delivered to slices. After a stable ED event was recorded, magnetic fields of 0.5 Hz (30 min) with a magnetic intensity of 0.13 mT (5 Vpp voltage input) and 0.25 mT (20 Vpp voltage input) were applied. The results indicated that a high-amplitude 0.5 Hz magnetic field could lead to persistent suppression of ictal discharges (IDs), while low-amplitude magnetic fields did not influence IDs. The persistent suppression of complex ED was prevented if the magnetic fields were applied in the presence of 10 μmol/L bicuculline (BIC), a γ-aminobutyric acid type A (GABAA) receptor antagonist, while the application of BIC subsequent to a magnetic field application led to the reappearance of ID. The addition of BIC resulted in EDs that had previously been inhibited by magnetic fields, reappearing. Low-frequency magnetic stimulation was able to inhibit the conversion from interictal discharges (IIDs) or preictal discharges (PIDs) to IDs. This suppression was attributed to the modulation of GABAA receptor activity.
More Related Videos
09:07Electroconvulsive Seizures in Rats and Fractionation of Their Hippocampi to Examine Seizure-induced Changes in Postsynaptic Density Proteins
Published on: August 15, 2017
13:14Multi-electrode Array Recordings of Human Epileptic Postoperative Cortical Tissue
Published on: October 26, 2014