Related Experiment Video
Updated: Nov 4, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Correlation of End-Tidal Carbon Dioxide with Arterial Carbon Dioxide in Mechanically Ventilated Neonates: A Scoping
Ingra Pereira Monti Martins1, Adriane Muller Nakato2, Paula Karina Hembecker2
1Medical student, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, Paraná, Brazil.
Abstract:
Monitoring CO2 levels in intubated neonates is highly relevant in the face of complications associated with altered CO2 levels. Thus, this review aims to present the scientific evidence in the literature regarding the correlation between arterial carbon dioxide measured by non-invasive methods in newborns submitted to invasive mechanical ventilation. The search was carried out from January 2020 to January 2021, in the Scopus, Medline, The Cochrane Library, Web of Science, CINAHL and Embase databases. Also, a manual search of the references of included studies was performed. The main descriptors used were: "capnography," "premature infant," "blood gas analysis," and "mechanical ventilation." As a result, 221 articles were identified, and 18 were included in this review. A total of 789 newborns were evaluated, with gestational age between 22.8 and 42.2 weeks and birth weight between 332 and 4790 g. Capnometry was the most widely used non-invasive method. In general, the correlation and agreement between the methods evaluated in the studies were strong/high. The birth weight did not influence the results. The gestational age of fewer than 37 weeks implied, in its majority, a moderate correlation and agreement. Therefore, we can conclude that there was a predominance of a strong correlation between arterial blood gases and non-invasive methods, although there are variations found in the literature. Even so, the results were promising and may provide valuable data for future studies, which are necessary to consolidate non-invasive methods as a reliable and viable alternative to arterial blood gasometry.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Acute Respiratory Failure-III
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are...